HPC
Features
- Low-profile, occupying only 10U of rack space
- 2KW or 4KW plugging power system
- 13-slot high-current VXI backplane
- Plugging fan module with (2) 340 cfm fans
- 300 cfm of airflow at 0.125" of H2O restriction
- Intelligent monitoring with remote output
- VXI plug-and-play compliant for 1- and 2-tier receivers
- Temperature monitor and cable tray options
- TÜV Product Service certified to EN60950
- High-performance digital test ready
The Tracewell HPC VXI is the industry’s highest performance 13-slot, C size VXI chassis. Featuring increased power and cooling, system monitoring, and a rugged modular design, HPC VXI is ideal for the latest generation of high-performance VXI instrumentation.
Capable of delivering over 3000W through the backplane, the Tracewell HPC VXI is available with single or dual power supplies that plug directly into the backplane, eliminating high-current DC wiring while providing exceptional dynamic load response. To efficiently manage this amount of power, the 13-slot backplane uses a unique power distribution scheme and special high current DIN connectors. The high-flow fan module is also pluggable and supplies 300 cfm of airflow at 0.125" of H2O board restriction in a fully loaded chassis.
Tracewell HPC VXI also features comprehensive system monitoring. This intelligent system provides a warning to the operator when power and cooling readings go out of tolerance. The power monitor continuously verifies all seven VXI DC voltages, and has the unique ability to notify the user of a past voltage fault even if it returns to normal. The cooling monitor verifies fan function and is also available with a temperature monitor option. In the event a cooling fault is detected, the monitor shuts down the system to prevent costly damage to the installed VXI boards. A front panel display provides local status for power and cooling, as well as other major system functions. In addition, a rear connector outputs both power and cooling monitor information for remote site operation.
This VXI plug-and-play compatible chassis occupies just 10U of rack space and is designed to accommodate a single-tier receiver assembly. Using the optional extender kit, double-tier receiver assemblies can also be used. Other options include bottom-mounted cable tray and rack slides.
Ordering Information
| Part Number | Description |
| 590-1006-F00-01 | HPC-2K chassis with 2KW power system |
| 590-1006-F00-02 | HPC-2K chassis with 2KW power system, multi-point temperature monitor |
| 590-1003-F01-01 | HPC-4K chassis with 4KW power system |
| 590-1003-F01-02 | HPC-4K chassis with 4KW power system, multi-point temperature monitor |
Accessories
| Part Number | Description |
| 106-1006-099-01 | Non-shielded single-slot filler panel, 6U X 8T; installs in vacant slots |
| 590-1105-C00-00 | 13U adapter kit for single-tier Virginia Panel Series 90 receiver |
| 590-1102-C00-00 | 13U adapter kit for double-tier Virginia Panel Series 90 receiver |
| 590-1101-C00-00 | Cabletray (2U) kit |
Note: The HPC product line is specially designed for use with Teradyne M9xx high-performance VXI digital test modules. These modules require a VXI backplane voltage setting of -2.2Vdc for proper operation. All HPC chassis part numbers above are shipped with this -2.2V output setting. As an order option, Tracewell can provide HPC chassis pre-configured with the VXI specified -2.0Vdc output for applications that do not use Teradyne M9xx modules and specifically require the VXI specified output. Please contact Tracewell for more details.